TM 5-4310-386-14
4-37. Oil Bath Air Filter Assembly (Cont).
c. Repair. (figure 4-47)
(1) Remove oil bath air filter assembly (para. b. above).
(2) Loosen screw (1) on clamp (2).
(3) Slide clamp (2) and base pad (3) down off of plate support (4) and remove clamp (2) and base pad (3).
(4) Remove plate support (4) and gasket (5).
(5) Release two clips (6) on filter housing (7) and remove bowl (8) and metal filter (9).
(6) Remove metal filter (9) from bowl (8).
(7) Pour oil from bowl (8) into suitable container.
(8) Remove gasket (10) and (11) from housing (7) and metal filter (9).
WARNING
Dry cleaning solvent PD-680 used to clean parts is potentially dangerous to personnel and
property. Avoid repeated and prolonged skin contact. Do not use near open flame or excessive
heat. Flash point of solvent is 138°F (60°C).
(9) Clean all items with dry cleaning solvent and dry thoroughly.
(10) Inspect all items and replace any item if crack or otherwise damaged.
(11) Fill bowl (8) with oil up to bead mark.
(12) Install gasket (11) on housing (7) and gasket (10) on metal filter (9).
(13) Install metal filter (9) into bowl (8).
(14) Install bowl (8) on housing (7) and secure with two clips (6).
(15) Position plate support (4) and gasket (5) on housing (7).
(16) Slide base pad (3) and clamp (2) upward over plate support (4) and tighten screw (1).
(17) Install oil bath air filter assembly (para. b. above).
FOLLOW-ON MAINTENANCE
Install prefilter (para. 4-36).
4-118