TM 5-4310-386-14
4-37. Oil Bath Air Filter Assembly .
This task covers:
a.
Service
b.
Replace
c.
Repair
INITIAL SETUP
Materials/Parts
Equipment Condition
Oil Bath Air Cleaner Assembly Filter
Compressor unit shut down (para. 2-13).
Solvent, Dry Cleaning (Item 24, Appendix E)
Prefilter removed (para. 4-36).
Rags, Wiping (Item 21, Appendix E)
Oil (Item 16, Appendix E)
Brush (Item 6, Appendix E)
a. Service. (figure 4-45)
(1)
Release two clips (1) on filter housing (2) and remove bowl (3) and metal filter (4).
(2)
Remove metal filter (4) from bowl (3).
(3)
Pour oil from bowl (3) into suitable container.
(4)
Clean housing (2), bowl (3), and metal filter (4) with dry cleaning solvent and brush. Blow dry with
compressed air.
WARNING
Dry cleaning solvent PD-680 used to clean parts is potentially dangerous to personnel and
property. Avoid repeated and prolonged skin contact. Do not use near open flame or excessive
heat. Flash point of solvent is 138°F (60°C).
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use only with
protective equipment (goggles/shields, gloves, etc.). Failure to do this may result in injury.
(5)
Fill bowl (3) with oil up to bead mark.
(6)
Install metal filter (4) in bowl (3).
(7)
Install bowl (3) on housing (2) and secure with two clips (1).
4-114