TM 5-4310-386-14
4-45. Battery, Cover, and Cables.
This task covers:
a.
Test
b.
Replace
INITIAL SETUP
Tools
Equipment Condition
General Mechanic's Tool Kit
Compressor unit shut down (para. 2-13).
(NSN 5180-00-177-7033)
Materials/Parts
Battery
Water, Distilled (Item 9, Appendix E)
a. Test. (figure 4-58)
WARNING
Lead acid batteries contain a strong acid. This acid can cause severe skin burns.
Handle battery only with proper lifting strap. Wear protective clothing and eye
protection.
(1)
Unlatch two latches (1) and remove cover (2).
(2)
Remove cap (3) and check electrolyte condition with hydrometer.
(3)
Check level of electrolyte, and add distilled water if level is low.
(4)
Install cap (3).
(5)
Repeat steps 1 and 2 for remaining battery cells.
(6)
Install cover (2) and secure with two latches (1).
4-142