TM 5-4310-386-144-45. Battery, Cover, and Cables.This task covers: a.Testb.ReplaceINITIAL SETUPToolsEquipment ConditionGeneral Mechanic's Tool KitCompressor unit shut down (para. 2-13).(NSN 5180-00-177-7033)Materials/PartsBatteryWater, Distilled (Item 9, Appendix E)a. Test.(figure 4-58)WARNINGLead acid batteries contain a strong acid. This acid can cause severe skin burns.Handle battery only with proper lifting strap. Wear protective clothing and eyeprotection.(1)Unlatch two latches (1) and remove cover (2).(2)Remove cap (3) and check electrolyte condition with hydrometer.(3)Check level of electrolyte, and add distilled water if level is low.(4)Install cap (3).(5)Repeat steps 1 and 2 for remaining battery cells.(6)Install cover (2) and secure with two latches (1).4-142