TM 5-4310-386-14
5-7. Control Panel Assembly (Cont).
b. Repair. (figure 5-2)
(1) Remove nut (1), washers (2), ground wire (3), washer (4), and screw (5).
(2) Remove five nuts (6), washers (7), absorbers (8), washer (9), and screws (10).
(3) Remove nut (11), washer (12), ground wire (13), and screw (14).
(4) Remove three nuts (15), washers (16), and screws (17).
NOTE
There are eight placards on the control panel. The number of rivets holding each placard varies.
Replacement of each placard is the same.
(5) Remove rivets (18) and remove placards (19) from control panel (20).
WARNING
Dry cleaning solvent PD-680 used to clean parts is potentially dangerous to personnel and
property. Avoid repeated and prolonged skin contact. Do not use near open flame or excessive
heat. Flash point of solvent is 138°F (60°C).
(6) Clean all items with dry cleaning solvent and dry thoroughly.
(7) Inspect all components and replace any component that is damaged.
(8) Install placards (19) and secure with rivets (18).
(9) Install three screws (17), washers (16), and nuts (15).
(10) Install screw (14), ground wire (13), washer (12), and nut (11).
(11) Install five screws (10), washers (9), absorbers (8), washers (7), and nuts (6).
(12) Install screw (5), washers (4), ground wire (3), washer (2), and nut (1).
FOLLOW-ON MAINTENANCE
(1) Install controls and indicators (para. 5-8).
(2) Install controls and indicators (para. 4-19).
5-12