TM 5-4310-386-14
5-26. Air Purification Group.
This task covers:
Service
INITIAL SETUP
Tools
Equipment Condition
Purification Wrench (WHR-2)
Compressor unit shut down (para. 2-13).
Materials/Parts
Reference
Cartridges
Cleaning Procedures, Chapter 4, Section VII.
Preformed Packings
Replace. (figure 5-38)
WARNING
Cleanliness is imperative in maintaining and handling diving system components. All tools and
parts must be kept free of oil, grease, rust, or other contamination in accordance with Chapter 4,
Section VII of this manual. Foreign substances within an assembly could result in equipment
failure and possible injury or death to personnel.
Ensure that all air lines and components removed or openings into the air system that provides
breathing air are covered with a plastic bag and secured with a rubber band or taped shut. Small
components should be stored in a plastic bag and sealed. Failure to do so will cause air system
to become contaminated and could result in injury or death to the diver.
NOTE
There are two cartridges PN 058827-410, and 058825-410, and both must be replaced at same
time. Replacement of each cartridges is the same.
(1)
Unscrew top plug (1) from cylinder (2).
(2)
Remove and discard preformed packing (3) from top plug (1).
(3)
Remove and discard cartridge (4).
CAUTION
Cartridges must be protected from absorbing moisture. Do not remove wrapper from new
cartridge until ready to install. Do not handle new cartridge with bare hands; use lint free cloth
or plastic cartridges wrapping.
(4)
Install cartridge (4) into cylinder (2).
(5)
Install preformed packing (3) on top plug (1).
(6)
Install top plug (1) on cylinder (2).
5-114