TM 5-4310-386-14
5-27. Purification Cylinders.
This task covers:
a.
Replace
b.
Repair
INITIAL SETUP
Tools
Materials/Parts (Cont)
General Mechanic's Tool Kit
Bands, Rubber (Item 4, Appendix E)
(NSN 5180-00-177-7033)
Materials/Parts
Equipment Condition
Purification Cylinder
Compressor unit shut down (para. 2-13).
Detergent, Nonionic (Item 8, Appendix E)
Purification cartridges removed (para. 5-26).
Distilled Water (Item 9, Appendix E)
Tape (Item 25, Appendix E)
Reference
Bags, Plastic (Item 3, Appendix E)
Cleaning Procedures, Chapter 4, Section VII.
a. Replace. (figure 5-39)
WARNING
Cleanliness is imperative in maintaining and handling diving system components. All tools and
parts must be kept free of oil, grease, rust, or other contamination in accordance with Chapter 4,
Section VII of this manual. Foreign substances within an assembly could result in equipment
failure and possible injury or death to personnel.
Ensure that all air lines and components removed or openings into the air system that provides
breathing air are covered with a plastic bag and secured with a rubber band or taped shut. Small
components should be stored in a plastic bag and sealed. Failure to do so will cause air system
to become contaminated and could result in injury or death to the diver.
(1)
Loosen coupling (1) and remove line (2).
(2)
Loosen union (3).
(3)
Remove two nuts (4), washers (5), and screws (6) from top and bottom split brackets (7).
(4)
Remove cylinder (8).
(5)
Remove union (3) from coupling (9).
(6)
Loosen union (10).
(7)
Remove two nuts (11), washers (12), and screws (13) from top and bottom split brackets (14).
5-116