TM 5-4310-386-14
o.
Check COMPRESSOR OIL PRESSURE gage (8) for reading in range of 750 to 800 psi (5171.25 to 5516
kPa).
p.
Set SAFETY BYPASS switch (5) to OFF position.
q.
Set CONDENSATE HEATER switch (10) to ON position and verify CONDENSATE HEATER lamp (11) is lit.
r.
Compressor is now operational.
s.
Mandatory requirements as follows:
WARNING
Failure to operate the condensate drain switch at the directed time intervals may cause air to
become contaminated and endanger personnel.
(1)
Every 15 minutes, press and hold the CONDENSATE DRAIN switch (12) in the ON position for six
seconds.
(2)
During high humidity and temperature, the CONDENSATE DRAIN switch (12) must be activated every
10 minutes.
2-13. Shut-Down Procedures. (figure 2-5)
CAUTION
Diesel engine should not be suddenly shut down from full-load condition.
a.
Press button on top of engine throttle control (1) and push engine throttle control all the way in until it stops,
then release button. Engine should be idling.
b.
Disengage clutch by pulling clutch lever (2) forward (towards front of unit).
c.
Set ENGINE RUN/STOP switch (3) to STOP position and hold in STOP position until engine completely
stops. Release engine RUN/STOP switch.
d.
Set CONDENSATE HEATER switch (4) to OFF position and verify lamp (5) is not lit.
e.
Turn ignition switch (6) to OFF position.
f.
Open bleed valve (7).
g.
Close service line control value (8).
2-13