TM 5-4310-386-14Table 4-1. Unit Preventive Maintenance Checks and Services (PMCS).W - WeeklyM - MonthlyS - SemiannuallyH - HourlyIntervalItemNo.WMSHItem to be InspectedProcedures8*Purification cartridgesInspect cartridges for cracks, loose, damaged,or missing parts. Notify your supervisor forcartridge replacement.TemperatureHours BetweenTemperatureHours BetweenF°/C°ReplacementF°/C°Replacement122/491568/2075115/461965/1886110/432260/15104105/402455/13117100/372950/1013595/353245/717280/323840/420175/246035/223470/217332/0285* Refer to table above for hours of operation between purification cartridgereplacement. Identify the closest temperature to the temperature at which theequipment has been operated in and compare the hours of operation against thevalue in the table. Take in consideration all hours the equipment was operatedabove or below that temperature.9Compressor drive beltInspect drive belt for wear, fraying, peeling,cracking, and tension. Replace and adjust belt asneeded (para. 4-25).10EngineInspectInspect for cracks, loose, damaged, or missingparts.250 ServiceService engine. Refer to para. 4-29.4-14