TM 5-4310-387-14
5-14. Final Separator Assembly (Cont).
b.
Repair. (figure 5-12)
WARNING
Cleanliness is imperative in maintaining and handling diving air system components. All tools
and parts must be kept free of oil, grease, rust, or other contamination in accordance with Chapter
4, Section VI of this manual. Foreign substances within an assembly could result in equipment
failure and possible injury or death to personnel.
Ensure that all air lines and components removed or openings into the air system that provides
breathing air are covered with a plastic bag and secured with a rubber band or taped shut. Small
components should be stored in a plastic bag and sealed. Failure to do so will cause air system to
become contaminated and could result in injury or death to the diver.
(1)
Remove final separator (para. a.).
(2)
Unscrew filter bowl cylinder (1) and remove.
(3)
Remove preformed packing (2). Discard preformed packing (2).
(4)
Remove tube assembly (3).
(5)
Inspect filter bowl cylinder (1) and replace if dented, cracked, or threads are stripped.
(6)
Inspect tube assembly (3) and replace if bent, cracked, or other damaged.
(7)
Inspect end cap (4) and replace if cracked, or threads are damaged.
(8)
Install tube assembly (3).
(9)
Apply halo carbon grease to new preformed packing (2).
(10)
Install new preformed packing (2) and filter bowl cylinder (1).
(11)
Install final separator (para. a.).
5-32