TM 5-4310-387-14
5-37. Pressure Maintaining Valve.
This task covers:
Replace
INITIAL SETUP
Tools
Equipment Condition
General Mechanic's Tools Kit (NSN 5180-00-177-7033)
Compressor unit shutdown and depressurized
(para 2-12).
Materials/Parts
Reference
Pressure Maintaining Valve
Tape, Teflon (Item 23, Appendix E)
Cleaning Procedures, Chapter 4, Section VI.
Bags, Plastic (Item 3, Appendix E)
Bands, Rubber (Item 4, Appendix E)
Tape, Pressure Sensitive (Item 22, Appendix E)
Replace. (figure 5-51)
WARNING
Cleanliness is imperative in maintaining and handling diving air system components. All tools
and parts must be kept free of oil, grease, rust, or other contamination in accordance with
Chapter 4, Section VI of this manual. Foreign substances within an assembly could result in
equipment failure and possible injury or death to personnel.
Ensure that all air lines and components removed or openings into the air system that provides
breathing air are covered with a plastic bag and secured with a rubber band or taped shut. Small
components should be stored in a plastic bag and sealed. Failure to do so will cause air system
to become contaminated and could result in injury or death to the diver.
(1)
Loosen two connector nuts (1) and remove line (2).
(2)
Loosen two connector nuts (3) and remove line (4).
(3)
Loosen connector nut (5) and remove charging whip (6).
(4)
Loosen connector nut (7).
(5)
Remove two screws (8) and washers (9), and remove pressure maintaining valve (10).
(6)
Remove elbow (11) and two fittings (12).
5-112