TM 5-4310-387-14
WARNING
Leave 1 1/2 threads exposed on fitting when applying tefIon tape. This will ensure that no tefIon
tape will hang down inside the air system. Teflon tape should be wrapped in such a manner that
when the fitting is tightened the tape will not loosen. Failure to wrap tefIon tape correctly may
result in contamination or blockage of the air system and subsequent possible injury or death to
the diver.
(7)
Apply tefIon tape to threads on two fittings (12) and elbow (
11).
(8)
Install elbow (11) and two fittings (12).
(9)
Install pressure maintaining valve (10) and secure with two screws (8) and washers (9).
(10)
Tighten connector nut (7).
(11)
Install charging whip (6) and tighten connector nut (5).
(12)
Install line (4) and tighten two connector nuts (3).
(13)
Install line (2) and tighten two connector nuts (1).
5-115