TM 5-4310-389-14
3-43 SEPARATOR BLOCK.
DESCRIPTION
This task covers:
Inspect
INITIAL SETUP
Tools:
Equipment condition:
General Mechanic Tool Kit
Compressor unit operating
Materials/parts:
Detergent, item 13 Appendix E
Water, item 32 Appendix E
INSPECT
a.
Inspect exterior for damage, corrosion, loose fittings, and loose mounting bolts (figure 3-46). Perform leak test
using non-ionic soapy water. Rinse and allow to dry.
NOTE
If compressor unit is at 5000 psi, fourth stage relief valve will be lifted.
b.
Check proper operation of the condensate drain by activating drain switch. Condensate should drain.
3-79