TM-5-4310-389-14
1.
Measuring procedure: a) adjust cylinder meter (figure 4-2), b) Measure cylinder, c) determine the
measuring points (figure 4-3) and compare with table 4-8.
2.
Cylinder measuring points: measure at four points in longitudinal direction A and four points at 90 degrees
to the longitudinal direction of the crankshaft B (figure 4-3).
NOTE
The high-pressure stage can only be measured with special measuring instruments.
Figure 4-2. Installing Cylinder Meter
Figure 4-3. Measuring Cylinder
4-26