TM-5-4310-389-14
Table 4-10. Run Solenoid Resistance Values
Multimeter
Function
Setting
Wire
Wire
Value
Hold
2000
Red #9
Black #2
10 to 20Q
Pull
200w
White #8
Black #2
2 to .3*
N/A
200w
Red #9
White #8
10 to 20Q
N/A
2OK2
All Wire
Body
Open
*Pull coil resistance is difficult to check, but will normally read an open circuit if defective.
NOTE
Ensure that the solenoid body has a proper ground before discarding.
5.
Reassemble solenoid on engine, but do not reconnect the black to #2 white.
6.
Ground the black wire directly to the solenoid mount frame and attempt restart. If this procedure works,
ground the instrument panel to the frame.
NOTE
Do not energize the coil when body is off the condensate valve body. Damage to coil will occur.
b.
Condensate Drain Coil.
1.
Remove condensate drain coil by loosening the nut on the top and disconnecting the electrical connection.
Figure 4-75. Condensate Drain Coil Test Points