TM-5-4310-389-14
Figure 2- 6. Decompression Device
Figure 2-7. Cranking Device
b.
Manual Start (Battery Dead and Alternator Not Producing Voltage).
1.
Place crank bungie cord from run solenoid to muffler guard.
2.
Remove condensate drain solenoid and remove the cylindrical valve from the condensate block.
3.
Remove the spring from the piston and reinstall the piston into the cylindrical valve and reinstall (solenoid
does not have to be reinstalled, but should be placed over the cylindrical valve to prevent damage.
4.
Turn throttle two turns from the IDLE position.
5.
Turn decompressor lever counterclockwise until it stops.
6.
Place crank in crank hole and turn counterclockwise (engine will turn freely for approximately six turns before
compression).
7.
Allow warm-up, then bring to full throttle and engage clutch.
CAUTION
No safety devices will activate during this start-up procedure.
2-12