TM-5-4310-389-14
8.
AR safety functions are bypassed; monitor compressor unit control panel to ensure proper operation.
9.
To bleed condensate, insert a 5/32-inch maximum diameter or smaller wire in the top of the solenoid valve to
release pressure.
c.
Manual Shutdown.
1.
Disengage clutch and allow engine to cool down.
2.
Remove bungie cord from engine run solenoid.
3.
Reassemble solenoid.
2-11 SHUTDOWN PROCEDURE.
CAUTION
Diesel engine should not be suddenly shut down from full-load condition.
a.
Disengage clutch.
b.
Set throttle to idle (push in and let idle two to three minutes).
c.
If condensate heater is operating, flip switch to OFF position.
d.
Turn ignition switch (8, figure 2-1) to OFF.
e.
Close service line control valve (14, figure 2-1).
f.
Allow unit to cool and cover with tarpaulin.
2-12 PREPARATION FOR MOVEMENT.
a.
Bleed off all system air pressure via bleed valve. See figure 2-3.
b.
Loosen all drive belts.
c.
Close and secure all valves.
d.
Disconnect and remove battery.
e.
Cover air intakes for engine and compressor. Cover exhaust manifold.
2-13