TM 5-4310-451-14
4-49. THERMOSTAT, THERMOSTAT COVERS, WATER OUTLET, AND CROSSOVER TUBE
REPLACEMENT (Cont).
24.
Remove bolt (60) and lockwasher (59) from right
water outlet (48). Discard lockwasher.
25.
Remove bolt (62), washer (61), and lockwasher
(63) from right water outlet (48). Discard
lockwasher.
26.
Remove bolt (55), lockwasher (56), right water
outlet (48), and gasket (57). Discard lockwasher
and gasket.
27.
Remove plug (58) from right water outlet (48).
b. INSTALLATION
1.
Install plug (58) into right water outlet (48).
2.
Apply adhesive to new gasket (57) and install on right water outlet (48).
3.
Install right water outlet (48) with new lockwasher (56) and bolt (55).
4.
Install new lockwasher (63), washer (61), and bolt (62) on right water outlet (48).
5.
Install new lockwasher (59) and bolt (60) on right water outlet (48).
TA704773
4-100