TM 5-4310-451-14
Table 2-1. Operator/Crew Preventive Maintenance Checks and Services (PMCS) (Cont).
B-BEFORE
D-DURING
A-AFTER
W-WEEKLY
INTERVAL
ITEM TO BE INSPECTED
EQUIPMENT IS NOT
ITEM
B
D
A
W
PROCEDURE: CHECK FOR AND HAVE REPAIRED,
READY/AVAILABLE IF
NO.
FILLED, OR ADJUSTED AS NEEDED.
12
FIRE EXTINGUISHER
WARNING
Handle charged fire extinguisher cylinders with
care. DO NOT jar or expose cylinder to
temperatures above 140 °F (60 °C). Failure to
follow this warning may cause an explosion,
resulting In serious Injury or death to personnel.
NOTE
Refer to TB 5-4200-200-10 for guidance on fire
extinguishers.
Check for broken or missing seal. Check security of
Seal is broken or missing.
mounting device
Fire extinguisher is missing.
13
EXHAUST SYSTEM
WARNING
Before checking any part of exhaust system, allow
exhaust system to cool. Failure to follow this
warning may result In serious burns.
Visually check exhaust system for signs of leaks,
Exhaust system has signs of
cracks, or breaks and loose or missing mounting
leaks, cracks, or breaks.
clamps
Mounting clamps are loose or
missing.
14
INSTRUMENTS AND GAGES
Check for proper indication and operation:
(1) Engine Oil Pressure
40-60 psi
Not within normal operating
(276-414 kPa)
range or nonoperational.
at 1050 rpm
(2) Air Compressor
Discharge
Temperature
180°F (82°C)
Not within normal operating
normal operating
range or nonoperational.
pressure
2-12