TM 5-4310-451-14
2-11.
DURING OPERATION.
CAUTION
Care must be taken to prevent air In fuel system. Never allow fuel tank to run dry. Air In fuel
system will cause engine powerloss, rough running, or engine to stall and not restart.
Ensure that all doors are closed for proper cooling and noise suppression.
a.
General.
(1)
Perform all During (D) PMCS.
(2)
Become familiar with the normal operation of the air compressor unit and with readings or Indicators.
Damage to equipment, extensive repairs, and downtime can be avoided by an alert operator who car detect problems In
early stages and help Unit Maintenance correct them before they become serious.
b.
Discharge Pressure Operation.
NOTE
Perform this adjustment If air compressor does not discharge at 100 psi (690 kPa) during
operation.
(1)
While operating air compressor unit, turn
pressure regulating valve (1) clockwise to Increase or
counterclockwise to decrease discharge pressure.
(2)
Repeat step 1 until air pressure gage
reads 100 psi (689.5 kPa).
2-16