TM 5-4310-451-14
LUBRICATION CHART
COMPRESSOR, AIR: ROTARY SCREW, 750 CFM,
100 PSI, WHEEL-MOUNTED, DED
SULLAIR MODEL 750 DP
(NSN 4310-01-053-3891)
Intervals (on-condition or hard time) and related man-
hour times are based on normal operation. The man-
hour time specified is the time you need to do al services
prescribed for a particular interval. De-crease the
intervals if your lubricants are contaminated, or If you are
operating equipment under adverse conditions, including
longer-than-usual operating hours. The intervals may be
extended during periods of low activity. If extended,
adequate preservation precautions must be taken.
Dotted leader lines indicate lubrication Is required or both
sides of the equipment.
WARNING
Dry cleaning solvent, P-D-680, Is toxic
and flammable. Always wear
protective goggles and gloves, and
use only in a well-ventilated
area. Avoid contact with skin, eyes,
and clothes, and DO NOT breathe
vapors. DO NOT use near open flame
or excessive heat. The solvents
flash point Is 100°F-138°F (38°C-
59°C). If you become dizzy while
using cleaning solvent, Immediately
get fresh air and medical help. If
solvent contacts eyes, Immediately
wash your eyes and get medical aid.
Clean all fittings and area around lubrication points with
dry cleaning solvent (Item 38, Appendix E) or equivalent
before lubricating equipment. After lubrication, wipe off
excess oil or grease to prevent accumulation of foreign
matter.
The lowest level of maintenance authorized to lubricate a
point is indicated in parentheses by use of the following:
(C) Operator/Crew; or (O) Organizational Maintenance.
3-2