TM 5-4310-452-14Table 4-2. Mechanical Troubleshooting Procedures (Con't).MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION7. UNIT WILL NOT UNLOAD.Step 1. Check for blocked regulating valve inlet.Remove and clean regulating valve (see paragraph 4-94).Step 2. Check regulating valve adjustment.Adjust throttle control (see paragraph 4-25).Step 3. Check for defective blowdown valve.Replace blowdown valve (see paragraph 4-95).8. SAFETY RELIEF VALVE RELIEVES.Step 1. Check to see if safety valve pops off.Replace oil separator filter element (see paragraph 4-87).Step 2. Check to see if operating pressure is too high.Adjust throttle control (see paragraph 4-25).Replace unloader valve assembly (see paragraph 4-90).Remove and clean regulating valve (see paragraph 4-94).Replace safety relief valve (see paragraph 4-96).9. START PRESSURE TOO HIGH.Step 1. Check for blocked regulating valve inlet.Remove and clean regulating valve (see paragraph 4-94).Step 2. Check for defective blowdown valve.Replace blowdown valve (see paragraph 4-95).10. EXCESSIVE VIBRATION.Step 1. Check for loose fan hub.Tighten fan hub (see paragraph 4-92).Step 2. Check for bent or broken fan blades, Replace fan (see paragraph 4-92).4-14