TM 9-4310-394-13
Table 2-1. Operator Preventive Maintenance Checks and Services
for the Air Compressor Unit, Model PD32T5 - Continued.
Location
Item No.
Interval
Procedure
Not Mission Capable If:
Item to
Check/Service
31
During
INFLATION
Check that inflation gauge
Inflation gauge does not
GAUGE
operates to indicate air
operate.
pressure.
32
During
AIR GAUGE
Check that air gauge indic-
Air gauge does not indi-
cates 175-200 psi air pres-
cate 175-200 air pressure.
sure in receiver tank. If
pressure exceeds 200 psi,
shut down unit and notify
unit maintenance.
33
During
RELIEF VALVE
Activate relief valve and
Activated relief valve does
check that air is released
not release air.
from valve.
34
During
UNLOADER
Activate unloader valve and
Unloader valve does not
VALVE
check that air is released
release air when activated.
from valve.
35
During
UNLOADER
Check that muffler reduces
Muffler does not reduce air
VALVE
air noise when unloader
noise when unloader valve
MUFFLER
valve is activated.
is activated.
36
During
SAFETY VALVE
Pull ring on safety valve and
Air is not released from
check that air is released
safety valve when ring is
from valve.
pulled.
37
During
AIR RECEIVER
Check that air receiver
Air receiver tank leaks
tank does not leak air when
when pressurized.
tank is pressurized.
38
During
DRAIN COCK
Drain cock leaks air when air Drain cock leaks air when
receiver tank is pressurized.
air receiver tank is pres-
surized.
39
After
DRAIN COCK
Open drain cock on receiver
to drain condensation from
tank. Leave drain cock open.
CHASSIS
40
Before
INFORMATION
Inspect plates and decals
PLATES AND
for damage and readability.
DECALS
Check for loose or missing
mounting hardware.
2-10