TM 9-4310-394-13
WARNING
HIGH VOLTAGE
is used in operation of this equipment.
DEATH ON CONTACT
may result if personnel fail to observe safety precautions.
Never work on electrical equipment unless there is another person nearby who is familiar with operation
and hazards of equipment and who is competent in administering first aid. When technician is aided by
operators, he must warn them about dangerous areas.
Whenever possible, input power supply to equipment must be shut off before beginning work. Take
particular care to ground every capacitor likely to hold a dangerous charge. When working inside, after
power has been turned off, always ground every part before touching it. Be careful not to contact high
voltage connections when installing or operating this equipment.
Whenever nature of operation permits, keep one hand away from equipment to reduce hazard to current
flowing through vital organs of body. Do Not operate equipment without all guards, louvers, and covers in
place and tightly secured.
(1) Connect the positive connector of the power source to the top terminal of the motor starter solenoid.
(2) Connect the negative connector of the power source to the axle of the unit. Rotate the connector a little to
insure that the connector is in good contact with the metal of the chassis.
d. Connection of Air Hose To Unit. (Refer to Figure 2-2). Before the air compressor is fully operational, the air
hose must be installed onto the air receiver tank. To install the air hose, attach the air hose (7) into the air receiver tank
(8).
Figure 2-2. Refueling Air Compressor Unit.
2-13