TM 5-4220-227-14
6-8.
Shell Penetrators (Cont).
e.
Repair Electrical and Water Penetrator. (figure 6-10)
(1)
Remove electrical and water penetrator (para. a. above).
(2)
Clean all components using nonionic detergent cleaner and rinse with clean distilled water.
(3)
Inspect mounting flange (1) and replace if bent, cracked, stripped threads, or otherwise damaged.
(4)
Inspect elbow (2) and fittings (3), (4), and (5), and replace if stripped threads, cracks, or otherwise
damaged.
(5)
Inspect penetrator plate (6) and replace is stripped threads, bent, cracked, or otherwise damaged.
(6)
Apply grease to gasket (7) and preformed packing (8) and (9).
(7)
Install electrical and water penetrators (para. a. above).
Figure 6-10. Electrical and Water Penetrators, Repair.
6-24