TM 5-4220-227-14
6-8. Shell Penetrators (Cont).
g.
Repair Electrical/O2Penetrator. (figure 6-12)
(1)
Remove electrical/O2 penetrator (para. c. above).
(2)
Clean all components using nonionic detergent cleaner and rinse with clean distilled water.
(3)
Inspect flange (1) and replace if stripped threads, bent, cracked, or otherwise damaged.
(4)
Inspect two tube unions (2), male tube connector (3), fitting (4) and replace if stripped threads, bent,
cracked, or otherwise damaged.
(5)
Inspect electrical penetrator (5) and replace if stripped threads, cracked, or otherwise damaged.
(6)
Apply grease to two preformed packings (6).
(7)
Install electrical/O2 penetrator (para. c. above).
Figure 6-12. Electrical/O2 Penetrator, Repair.
6-26