TM 5-4220-227-14
f.
Repair Oxygen Penetrator. (figure 6-11)
(1)
Remove oxygen penetrator (para. a. above).
(2)
Clean all components using nonionic detergent cleaner and rinse with clean distilled water.
(3)
Inspect flange (1) and replace if stripped threads, bent, cracked, or otherwise damaged.
(4)
Inspect two tube unions (2), male tube connector (3), fitting (4), and plug (5), and replace if stripped
threads, bent, cracked, or otherwise damaged.
(5)
Apply grease to preformed packing (6).
(6)
Install oxygen penetrator (para. b. above).
Figure 6-11. Oxygen Penetrator, Repair.
6-25