shall be 3050 psig (214.4150 kgs per sq cm)-3350 (235.5050 kgs per sq cm) psig.
2. Gradually reduce the test pressure until the control valve deactivates (clicks and lever moves to UP
position). Actuating pressure lever moves to DOWN Position). Deactivating pressure shall be 2650 psig
(186.2950 kgs per sq cm)-2950 (207.3850 kgs per sq cm) psig.