TM 5-4310-352-14
adjusting the flow of filtered dry air into a reduced pres-
f.
sure when required for instrument repair, or other delicate
screwed into the air receiver at the point where the after-
use.
cooler line enters the air receiver. This check valve pre-
h. Pilot Valve (unloader). The unloader pilot valve
vents air from receiver returning to the compressor after it
has stopped, and the unloaded pilot valve has released all
cylinders when compressor is stopped, for ease in start-
pressure inside the air compressor.
ing the compressor without tripping the motor overload
g. Pressure Regulating Valve. The pressure regu-
Figure 2-1. Air compressor controls and instruments (Sheet 3 of 3).
2-3