Table 3-2. Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Step 1. Check for a clogged muffler
a. Service the muffler intake filter
intake filter.
Step 2. Check oil level.
The oil level gage mounted in the
reading, glass covered gage used to check
If the oil level is low, remove the oil fill
lubrication oil, to the full mark on the oil
sight gage. Replace the fill plug.
2.
Knocks or Rattles
Step 1. Check for loose, damaged
Notify organizational maintenance.
Step 2. Check for leaking valves,
Notify organizational maintenance
or restricted air passages.
3.
Air Delivery Dropping
Step 1. Check for a clogged
a. Service the muffler intake filter
muffler intake filter.
4.
Excessive Starting and
Step 1. Check the receiver.
Drain the air receiver.
Stopping
a. Turn ON-OFF switch to OFF.
b. Open draincock at the bottom of the air
c. When the air has escaped, leave draincock
open for a few minutes for more of
condensate to escape.
d. Close draincock.
e. Be sure that cleaning material and tools
have been removed from the air receiver.
f. Move the ON-OFF switch to ON.
Step 2. Check for air leaks in
a. Make a solution of soapy water.
the piping.
b. Apply to the fittings. If a leak is present
it will be indicated by the soapy water
bubbling.
c. If a leak is found, notify organizational
maintenance.
3-5