TM 5-4310-360-14
2-5. Operating Procedure
a.
General. The operator must know how to
perform every operation of which the air
compressor is capable. This section gives
instructions on starting and stopping the air
pressor, and on coordinating basic motions
to perform specific tasks for which the
equipment is designed. Since nearly every
job presents a different problem, the
operator may have to vary given procedures
to fit the individual job.
WARNING: Operation of this equipment
presents a noise hazard to personnel in the
area. The noise level exceeds the allowable
limits for unprotected personnel. Wear ear
muffs or earplugs which were fitted by a
trained professional.
for charging cylinders that require breath-
able air.
Preparation for Starting. Perform the neces-
b.
sary Before Operation Preventive Services
C.
Starting.
Turn ignition switch (1) on.
(1)
Open draincock (2).
(2)
Close choke lever (3).
(3)
Raise the release valve (4) to
(4)
unload compressor.
W ind starter rope clockwise around
(5)
starter pulley (5).
W ith a quick, steady pull, start the
(6)
engine.
When engine starts, gradually open
(7)
choke lever (3).
Place release lever (4) in down
(8)
position.
I
Close draincock (2).
(9)
(10) Perform the necessary During Opera-
tion Preventive Services as indicated
(11) Watch for any ususual noise or
vibration.
Change 1 2-9