TM 5-4310-368-14
3-33.
AIR PRESSURE GAGES (Fig. 3-7)
a. Inspection. Inspect each air pressure gage for cracked or broken lens, oil leak, damaged or missing pointer,
damaged face, loose tube connections and hoose hardware.
b. Testing. Refer to general support maintenance.
c.
Replacement. Refer to direct support maintenance.
3-34. PANEL LAMP
a. Inspection.
(1) Inspect lamp bulb for operation.
(2) Inspect lamp fixture for loose or missing attaching hardware.
(3) Inspect lamp wiring for damage.
b. Testing. Turn on panel lamp switch. Insure both lamps operate.
c.
Replacement of Bulb.
(1) Push lightbulb in toward base of fixture and turn bulb counterclockwise 1/3 turn. Remove bulb.
(2) Align locating pins in base of bulb with slots in lamp fixture. Push bulb in toward base of fixture and turn
clockwise 1/3 turn. Release bulb.
d. Replacement of Lamp Fixture. Refer to organizational maintenance.
3-35. HOURMETER (Fig. 3-7)
a. Inspection. Inspect hourmeter for damaged lens or number wheels, loose hardware or loose or damaged wiring.
b. Testing. Use a stopwatch and verify accuracy of hourmeter.
c.
Replacement. Refer to organizational maintenance.
3-36.
AIR CLEANER INDICATOR (Fig. 3-5)
a. Inspection. Visually inspect air cleaner restriction indicator and sensor tube for damage and loose or missing
parts.
b
Replacement. Refer to organizational maintenance.
3-20