TM 5-4310-369-14
Table 2-1. Preventive Maintenance Checks and Services Continued
For Readiness Reporting,
Procedure
Interval
Equipment is Not
Item
Item to be
Check for and have Repaired
AW
Ready/Available If:
No.
Inspected
or Adjusted as Necessary
D
B
Inspect for damage and insecure
Controls and Instru-
3
Controls are damaged or
ments
mounting. With the unit oper-
loose.
ating, inspect for proper oper-
ation. Normal operating pressure
is 140-175 psi (9.8 -12.3 kg/sq cm).
4
Open draincock to drain water
Air Receiver Drain-
from the tank. After water is
cock (3)
drained, close draincock.
Should be checked with unit
5
Fuel Strainer
NOTE
shut down.
By keeping fuel tank full,
Check fuel level and fuel
6
Fuel Tank
to a minimum. This simple
strainer. (5)
preventive maintenance step
(taken at the end of each day)
will greatly reduce water
build-up in fuel tank.