a. Disconnect inflator gage hose from globe valve by turning hose connection nut counter clockwise (figure 4-11).
b. Disconnect inflator gage hose from inflator gage by turning inflator gage counter clockwise until disconnected
c. Leave globe valve closed.
d. Use thread tape or thread compound on globe valve bushing and install inflator gage hose into globe valve by
e. Use thread tape or thread compound on inflator gage hose and install in inflator gage by turning hose connection
f. Open globe valve and check connections for air leaks.
TM 5-4310-371-14/4-11
FIGURE 4-11. INFLATOR GAGE HOSE REPLACEMENT
4-14. INFLATOR GAGE REPLACEMENT.
WARNING
Close globe valve tightly to avoid personal injury.