TM 5-4310-376-14
Table 4-2. Organizational Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3. Check belt tension.
Step 4. Inspect mounting and foundation.
Tighten mounting bolts; strengthen foundation or relocate onto
solid base.
13. EXCESSIVE OIL CONSUMPTION, COMPRESSOR PUMP OR ENGINE.
Step 1. Check oil for proper weight and viscosity.
Use correct oil for operating conditions (para 3-1).
Step 2. Check for external leaks.
Tighten connection where oil is leaking.
Step 3. Check for loose oil filler caps.
Tighten.
14. NO AIR COMING OUT OF INFLATOR GAGE.
Step 1. Close globe valve and disconnect air hose; open globe valve and listen
for air. If air escapes, go to step 2; no air escaping, globe valve defec-
tive and/or air tank defective.
Step 2. Close globe valve, disconnect inflator gage from air hose and open globe
valve. If air is felt air hose is good; no air felt, air hose defective.
Air comes out of air hose, replace inflator gage (para 4-34). No
4-23