TM 5-4310-379-14
c.
Repair. (figure 3-50)
NOTE
Oil filter assembly removed for repair. See para. b above.
WARNING
Dry cleaning solvent PD-680 used to clean parts is potentially dangerous to personnel
and property. Avoid repeated and prolonged skin contact. Do not use near open flame
or excessive heat. Flash point of solvent is 100-138°F (38-60C).
(1) Clean all items with dry cleaning solvent and dry thoroughly.
(2) Inspect shell (1) and replace if cracked or other damaged.
(3) Inspect spring (2) and replace if bent, cracked or otherwise damaged.
(4) Inspect base (3) and replace if cracked or otherwise damaged.
(5) Inspect bolt (4) and replace if threads are stripped or bolt is otherwise damaged.
(6) Inspect washer (5) and replace if cracked or otherwise damaged.
(7) Inspect gasket (6) and replace if cracked, torn, or otherwise damaged.
(8) Replace oil filter (7).
3-118