TM 5-4310-382-13
Figure 2-2. Compressor Drive Belt Tension Adjustment.
2-6. OPERATING PROCEDURE. Paragraphs 2-8, 2-9, and 2-10 are to be
followed for start-up, operation and shut down
WARNING
DO NOT stand close to exhaust opening for long periods of time. Serious illness
or death can occur from carbon monoxide emitted from gasoline engine.
To avoid fire or explosion during engine refueling:
DO NOT allow any flame producing material within 50 feet (15.25 m).
DO NOT smoke while refueling.
DO NOT let gasoline drip onto hot surface.
DO NOT refuel while engine is running.
CAUTION
Perform all "before" operation preventive maintenance checks and services before
starting air compressor unit.
2-9