TM 5-4310-385-13
REMOVAL.
WARNING
Disconnect main power source and turn compressor unit OFF before performing
maintenance procedures. Voltages present in this equipment can cause injury or
death.
a.
Open cover (1) by turning key (2) and depressing latch on enclosure (3).
b.
Disconnect and tag all wires (7) from starter assembly.
c.
Loosen three screws (4) from base plate (5) and raise base plate up.
d.
Remove starter assembly (6) from enclosure (3).
e.
Remove conduit locknuts (8) and pull conduits and wires (9) from enclosure.
f.
Remove bolts, nuts, and washers (10) securing enclosure to saddle frame (11 ).
g.
Remove nut (12), ON/OFF plate (13) and toggle switch (14) from enclosure cover.
INSTALLATION.
a.
Position toggle switch (14) and ON/OFF plate (13) on enclosure cover and secure with nut (12).
b.
Install bolts, nuts, and washers (10) securing enclosure (3) to frame (11).
c.
Push power source conduit and motor wires (9) through holes in enclosure and secure with locknuts (8).
d.
Place starter assembly (6) into enclosure far enough to connect wires (9).
e.
Connect all wires (9) to starter assembly (6) as tagged.
f.
Install screws and washers (4) that secure starter assembly base plate (5) to enclosure.
CAUTION
Recheck all wiring connections before turning main power on. If not sure, refer to
wiring diagram.
g.
Close enclosure door.
h.
Reconnect main power.
3-14