TM 5-4310-386-14KeyControl or IndicatorFunction8Engine Run Stop SwitchSpring loaded toggle switch. When depressed energizesa solenoid which pushes the engine stop lever, thusshutting the engine down.9Ignition SwitchKey operated, three position (OFF, RUN, START) switch.Turning key to START position and pushing in startsengine. When engine starts, release key and turn to RUNposition. To stop engine, turn key to OFF position.10Relay Latch PushbuttonWorks in conjunction with ignition switch. Pushbutton ispushed in and held until engine started, then released.Activates automatic shutdown in case of excessive engineor compressor temperature or abnormal oil pressure.11Safety Bypass SwitchTurn position toggle switch. Used during cold weather forengine starts for clutch disengaged. Must be in ONposition when starting engine so that low oil pressuresafety on the compressor does not shut down engine.Once clutch is engaged, must be in OFF position12Condensate Drain SwitchTwo position (ON/OFF), spring loaded toggle switch.Causes all condensate drains to open when held in the ONposition. Normally held for six seconds every 15 minutesby operator.13Condensate Heater SwitchTwo position (ON/OFF) toggle switch. Controls the heaterfor the condensate valve assembly. Used in cold weatheronly.14Condensate Heater LampIndicates when condensate heater is on.15Service Line ValveControls air flow to the service line outlet.2-3