(3) Push the speed control lever (1) down to STOP position and hold lever down until engine stops.
(4) After engine has completely stopped, move speed control lever (1) to fast position.
(5) Release condensate and depressurize unit by means of condensate drain valves (4).
(6) Close drain valves (4).
(7) Pull cold start primer (5).
(8) Perform after operation PMCS (table 2-1).
Figure 2-7. Shutdown Procedures.