TM 5-4310-389-14
4-25. PURIFIER CHAMBER.
DESCRIPTION
This task covers:
Replace
Repair
INITIAL SETUP
Tools:
Equipment condition:
General Mechanic Tool Kit
1. Equipment secured
Securus wrench
(paragraph 2-11)
2. Bleed system of pres-
Materials/parts:
sure (paragraph 2-3)
Alcohol, Isopropyl, item 1 Appendix E
Apron, Rubber, item 5 Appendix E
Bag, Plastic item 6 Appendix E
Book, Record, item 7 Appendix E
Cloth, Lint-free, item 9 Appendix E
Detergent, Non-ionic item 13 Appendix E
Gloves, Rubber item 17 Appendix E
Grease, Halo Carbon, item 19 Appendix E
Shield, Face, item 26 Appendix E
Trisodium Phosphate, item 31 Appendix E
Water, Distilled, item 32 Appendix E
WARNING
Cleanliness is imperative in maintaining and handling diving system components. All tools and parts
must be kept free of oil, grease, rust, or other contamination in accordance with accepted Army diving
cleaning procedures. Foreign substances within an assembly could result in equipment failure and
possible injury or death to personnel.
WARNING
Any break in air system integrity can cause contamination of the air system. Serious injury or death
may result due to air system contamination. Follow Army diving cleaning procedures to maintain air
system integrity.
4-111