TM 5-4310-389-14
4-26. SEPARATOR BLOCK
DESCRIPTION
This task covers:
Replace.
Repair.
INITIAL SETUP
Tools:
Equipment conditions:
General Mechanic Tool Kit
Battery removed
Materials/parts:
Cloth, Lint-free, item 9 Appendix E
Detergent, Non-ionic, item 13 Appendix E
Grease, Halo Carbon, item 19 Appendix E
Rags, Wiping, item 26 Appendix E
Teflon Tape, item 30 Appendix E
WARNING
Cleanliness is imperative in maintaining and handling diving system components. All tools and parts
must be kept free of oil, grease, rust, or other contamination in accordance with accepted Army diving
cleaning procedures. Foreign substances within an assembly could result in equipment failure and
possible injury or death to personnel.
WARNING
Any break in air system integrity can cause contamination of the air system. Serious injury or death
may result due to air system contamination. Follow Army diving cleaning procedures to maintain air
system integrity.
a.
Remove (figure 4-72).
1.
Remove the six tubes that are attached to the top of the condensate blocks.
2.
Remove the condensate drain line (located on the bottom right hand side of the block.)
3.
Remove the four bolts securing the condensate block to the frame.
4-116