TM 5 4310-451-14
4-39. EMERGENCY STOP CABLE REPLACEMENT (Cont).
c.
ADJUSTMENTI
1.
Ensure that emergency stop control (11) is
pushed in on side panel (10).
2.
Ensure that lever (13) is in operational position.
3.
Measure distance from cable housing (12) to
lever (5). Distance should be 1.0 in. (2.5 cm).
NOTE
Perform steps 4 through 7 only If distance measurement
Is Incorrect.
4.
Loosen setscrew (6) and slide stop (7) toward
end of emergency stop cable (1).
5.
Loosen screw (4) and move bracket (3) until
cable housing (12) is 1.0 In. (2.5 cm) from lever
(5). Tighten screw.
6.
Slide stop (7) forward until approximately 0.06
in.(1.mm) from lever (5).
8.
Operate emergency stop control (11) and ensure
that emergency stop cable (1) is properly
adjusted; tripping to OFF position.
9.
Repeat steps 1 and 2.
TA704741
4-63