TM 5-4310-451-14
4-79. AIR COMPRESSOR DISCHARGE TEMPERATURE GAGE AND SWITCH ,
REPLACEMENT (Cont).
2.
Remove switch (7) from discharge valve (6).
3.
Remove two nuts (1), lockwashers (2), and bracket (3) from gage (5) and instrument panel (4). Discard
lockwashers.
4.
Remove gage (5) from instrument panel (4).
1.
Thread line (9) through Instrument panel (4) and position gage (5) on Instrument panel.
2.
Install bracket (3) on gage (5) and instrument panel (4) with two new lockwashers (2) and nuts (1).
3.
Install switch (7) on discharge valve (6).
4.
Install two leads (8) on switch (7).
TA704845
b. INSTALLATION
4-192