TM 5-4310-451-14
5-30. INJECTOR TUBE REPLACEMENT (Cont).
18.
Remove second operation reamer (11) and
clean filings from injector tube (2).
19.
Repeat steps 15 through 18 until measurement
given In step 13 is obtained.
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable.
Always wear protective goggles and gloves, and use only
In a well-ventilated area. Avoid contact with skin, eyes,
and clothes, and DO NOT breathe vapors. DO NOT use
near open flame or excessive heat. The solvents flash
point Is 100°F-138°F (38°C-590°C). If you become
dizzy while using cleaning solvent, Immediately get fresh
air and medical help. If solvent contacts eyes,
Immediately wash your eyes and get medical aid.
20. Clean Injector tube (2) with dry cleaning solvent.
FOLLOW-ON TASKS:
Install cam follower assemblies and pushrods (see paragraph 5-25
Install exhaust valve (see paragraph 5-24).
Install fuel injectors (see paragraph 5-57).
Install exhaust valve bridges (see paragraph 5-26).
Install rocker arms (see paragraph 5-41).
Install cylinder head (see paragraph 5-28).
TA704951
5-70