TM 5-4310-452-14
5-33. FIBERGLASS PANELS REPLACEMENT (Con't).
b. CLEANING
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Always wear protective goggles and
gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes, and
DO NOT breathe vapors, DO NOT use near open flame or excessive heat, The solvent's flash
point is 100°-130°F (38°C-59°C). If you become dizzy while using cleaning solvent, immediately
get fresh air and medical help. If solvent contacts eyes, immediately wash your eyes and get
medical aid.
1.
Clean fiberglass mounting surface with dry cleaning solvent and rags.
c. INSTALLATION
DOOR ASSEMBLIES
1.
Install new fiberglass panels (4, 8, and 15) in place on door assembly (16) with adhesive.
2.
Install door assembly (see paragraph 5-28).
TA505601