Home
Download PDF
Order CD-ROM
Order in Print
Organizational Preventive Maintenance Checks and Semites (PMCS) (Con't) - TM-5-4310-452-14_74
Section III. ORGANIZATIONAL TROUBLESHOOTING
TM-5-4310-452-14 Compressor Air: Rotary Screw 750 CFM 100 PSI Wheel-Mounted DED SULLIAR Model 750 DP Manual
Page Navigation
62
63
64
65
66
67
68
69
70
71
72
TM 5-4310-452-14
Table 4-1. Organizational Preventive Maintenance Checks and Services (PMCS) (Con't).
Q - Quarterly
S - Semiannual
H - Hours
INTERVAL
ITEM
ITEM TO BE INSPECTED
PROCEDURES
NO.
Q
S
H
10
AIR SILENCER
Remove, clean, and inspect air silencer (see paragraph 4-94).
11
DRAWBAR
Check drawbar mounting bolts for proper
torque
of
180-200 lb. -ft (244-271 N*m).
4-7/(4-8 Blank)