Figure 26. Control box disassembly.
Ignition

Lubricating And Servicing Unit, Power Operated, Skid Mounted, 16 Cfm Compressor Reciprocating, Power Driven, Winterized Page Navigation
  56    57    58    59    60  61  62    63    64    65    66  
img
. . . . . . . . . . . . . .
d. Reassembly.
(10) and at the reverse-current relay (8).
(10) Disconnect the relay-to-starter generator
(1) Position the resistor (10, fig. 26) in the
lead (9) at the reverse-current relay (8).
control box, and secure with the bolt (10,
fig. 25).
(11) Disconnect the fixed resistor-to-relay lead
(26) at the resistor and at the reverse-
(2) Position the resistor (18, fig. 26) in the
current relay.
control box, and secure with the screws.
(12) Disconnect the reverse-current relay lead
(3)
Install the stop button (7) to the stop
(5)  from  the  reverse-current  relay
switch.
terminals.
(4) Position the reverse-current relay (8) in
(13) Remove the two screws (11, fig. 25)
the control box, and secure with the two
which secure the reverse-current relay to
screws (11, fig. 25).
the control box, and remove the reverse-
(5)  Position the voltage regulator (27, fig. 26)
current relay.
in the control box, and secure with the two
(14) Disconnect the ground wire (17, fig. 26)
bolts (9, fig. 25).
from the stop switch (19), and unscrew
(6) Position the starter switch (24, fig. 26) in
the stop button (7, fig. 25) from the control
the control box, and secure with the two
box (23).
nuts (23).
(15) Remove the screw (6) which secures the
(7) Position the ammeter (21) in the control
resistor (18, fig. 26) to the control box,
box, and secure with the two nuts.
and remove the resistor.
(8) Connect the reverse-current relay lead (5)
(16) Remove the bolt (10, fig. 25) which
to the reverse-current relay terminals.
secures the resistor (10, fig. 26) to the
(9) Connect the resistor-to-relay lead (26) at
control box, and remove the resistor.
the resistor (18) and at the reverse current
c. Cleaning, Inspection, and Repair.
relay terminal.
(1) Clean all  parts,  using an approved
(10) Connect the relay-to-starter generator
cleaning solvent.
lead (9) at the reverse-current relay
terminal.
(2) Inspect the voltage regulator for proper
mounting and loose connections. Tighten
(11) Connect the relay-to-resistor lead (11) at
all loose connections.
the resistor (10), and at the reverse-
current relay terminal.
(3) If the voltage regulator shows a high-
charging rate or no-charging rate on the
(12) Connect the resistor-to-voltage regulator
ammeter, replace the voltage regulator.
lead (13) at the voltage regulator terminal
and at the resistor (10).
(4) Inspect the control box wiring for proper
connections.
Tighten  any  loose
(13) Connect  the  starter  switch-to-voltage
connections at the inside of the control
regulator lead (28), at the starter switch
box. Replace any defective wiring.
terminal nut (25), and at the voltage
regulator terminal.
(5)
Inspect the ammeter for cracked or
broken glass or  defective operation.
(14) Connect the ammeter-to-starter switch
Replace a defective ammeter.
lead (22) at the ammeter terminal nut and
at the starter switch terminal nut (25).
(6) Inspect the starter switch, and the stop
switch for loose connections,  proper
(15) Connect the ammeter-to-voltage regulator
mounting,  and  improper  operation.
lead (20) at the ammeter terminal nut,
Tighten loose stop switch or starter switch
and at the voltage regulator terminal nut
mounting  connections.
Replace  a
(12, fig. 25).
defective stop switch or starter switch.
(16) Connect the starter button leads (1) at the
starter switch terminal nuts (25) and at the
terminal screws (2).
62