TM 55-1905-223-24-8
2-28.
Replace/Repair Liquid Level Rod-Cap Gauge Assembly. (FIGURE 2-19)
This task covers:
a. Removal,
b. Repair,
c. Replacement.
INITIAL SETUP
Tools
Equipment Condition
Tool kit, general mechanic's,
shut down, tagged "Out of Service-
Do Not Operate."
Materials/Parts
Gage assembly P/N 6726X
Liquid level gauge rod P/N 5488
Filler opening cap P/N 6726
Preformed packing P/N 123157-210
REMOVAL
Unscrew gauge assembly by hand and pull from crankcase hole (4).
DISASSEMBLY
a.
Pull preformed packing (3) from cap (1) bottom.
b.
Pull rod (2) from cap (1).
REPAIR
a.
Inspect preformed packing for worn or torn ar as; rod for rust, chips, or bends; inspect cap for rust, corrosion,
e
or disfigured threads.
b.
Replace as necessary.
c.
Clean preformed packing.
d.
Clean cap and rod.
2-58