TM 9-4310-394-13
WARNING
Serious injury can result in breathing fumes of dry
cleaning solvent. Serious injury or death can result
from explosion of fumes from solvent. When using
this solvent:
Clean parts in a well ventilated area.
Avoid inhalation of solvent fumes and prolonged
exposure of skin to cleaning solvent. Wash
exposed skin thoroughly.
Do not use near open flame or excessive heat.
Flash point of solvent is 100° F to 138° F (38° C to
59° C).
Wear eye protection when blowing solvent from
parts. Air pressure should not exceed 30 psig (2.1
kg/cm2).
(2) Clean all metallic parts with a clean soft cloth or a medium bristle brush, and cleaning solvent.
(3) Allow parts to dry.
c.
Inspection. Inspect all metal parts for cracks, corrosion, or broken fittings.
d.
Repair. Repair is limited to replacement of parts found defective during inspection.
e.
Installation.
(1) Install safety valve (8) into intercooler tube (7).
(2) Install intercooler tube (7), two gaskets (6), and four screws (5).
(3) Install flywheel (4) onto unit.
(4) Install flat washer (3), lock washer (2), and screw (1). Refer to Appendix G for proper torque values.
Figure 4-21. Flywheel and Intercooler Tube Repair and Replacement.