TM9-4310-396-13
MAINTENANCE OF GAGES, SENSORS, KNOB, AND SPEED CONTROL
4-29.
REPLACE GAGES, SENSORS, KNOB, AND SPEED CONTROL.
This task covers:
a.
Removal
b.
Installation
INITIAL SETUP
Tools
Equipment Conditions:
General Mechanics Tool Kit Storage battery disconnected, para. 4-26
Materials/Parts
Brush, Cleaning (Appendix E, item 1)
Temperature Transmitter (P/N TS-1029)
Rag, Wiping (Appendix E, item 3)
Ampmeter Gage (P/N GP0528A)
Solvent, Dry Cleaning (Appendix E, item 2)
Temperature Gage (P/N GP0628A)
Tape, Teflon (Appendix E, item 6)
Pressure Gage (P/N G10057)
Liquid Level Gage (P/N GP0709)
Pressure Gage (P/N G-31653)
Liquid Level Switch (P/N LS1038)
Gasket (P/N 362GKT-FLS)
Time Totalizing Meter (P/N MH0042A)
a.
Remove Mechanical Gage.
WARNING
Dry cleaning solvent used to clean parts is potentially dangerous to personnel and
property. Clean parts in a well-ventilated area. Avoid inhalation of solvent fumes Wear
goggles or eye protection when blowing solvent from parts. Air pressure should not
exceed 30 psi (2.1 Kg/cm2). Wear rubber gloves to protect skin. Wash exposed skin
thoroughly. Do not smoke or use near open flame or excessive heat. Flash point of
solvent is 100°F to 138°F (380C to 59°C). Failure to observe this warning may result in
severe personal injury or death.
NOTE
Clean all parts and gages as necessary.
(1)
Remove tube nut (1, Figure 4-17) and nonmetallic tube (2) from gage (5).
(2)
Remove plain hexagon nuts (3) and bracket (4).
(3)
Remove gage (5).
4-53